SERIAL NUMBER (located on top of product): 08/29/12– MPCP-A Phone: 800-669-1303 or 801-561-0303 Fax: 801-255-2312 e-mail: treborservice@idexcorp.
PAGE 10 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL Figure 4-2: Pressure and Flow Capacity Chart The preceding chart defines a regi
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL PAGE 11 5 INSPECTION AND MAINTENANCE 5.1 MAINTENANCE The Purus CP has no serviceable parts. Pumps re
PAGE 12 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL 6 PC15 (OPTIONAL) INSTALLATION 6.1 PC15 OVERVIEW The PC15 Pump Controller is designed specific
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL PAGE 13 6.3 PC15 UTILITIES / HOOK-UP Utility Pump Air Inlet: 3/8” Diameter supply tube. Air Supp
PAGE 14 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL 6.4 PC15 CONTROLLER OPERATION Ensure that all system interlock and safety devices are function
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL PAGE 15 7 TROUBLESHOOTING 7.1 PUMP SYMPTOM CAUSES SOLUTIONS Bubbles in Fluid Discharge Diaphra
PAGE 16 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL 8 WARRANTY AND EXCLUSIONS See the Trebor Standard Limited Warranty at www.idex-hs.com/support
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL PAGE 17 9 CONTACT INFORMATION 9.1 GENERAL CONTACT INFORMATION Web: www.teborintl.com Phone Numbe
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL CONTENTS CONTENTS 1 INTRODUCTION ...
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL PAGE 3 1 INTRODUCTION Purus CP – A Revolutionary PFA High-Purity, Low-Pulsation Pump! TREBOR’S Purus
PAGE 4 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL 1.1 INTENDED USE AND AUDIENCE The Purus CP pump is designed to safely pump liquids up to 120°C.
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL PAGE 5 2 SAFTEY 2.1 SAFETY PRECAUTIONS This section provides important information for safe operation
PAGE 6 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL 3 INSTALLATION Ensure all system interlock and safety devices are functional prior to operation
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL PAGE 7 3.1 UTILITIES / HOOK-UP Utility Pump Air Inlet: 3/8” FNPT per head. Air Supply: 20-80
PAGE 8 PURUS CP PUMP OPERATION / MAINTENANCE MANUAL 4 OPERATION 4.1 PRINCIPALS OF OPERATION The Purus CP accomplishes near pulseless flow by Cr
PURUS CP PUMP OPERATION / MAINTENANCE MANUAL PAGE 9 Refer to Troubleshooting Section 7 if pump fails to start or contact Trebor for further ass